Motor Control · Product Selection Guide
A model-level checklist for selecting Eaton contactors correctly—especially coil voltage, auxiliary contact configuration and motor-duty ratings.
For contactors, the complete catalogue number matters. Two models with the same current rating can differ in coil voltage, auxiliary contacts, mounting details and motor-duty ratings, which can make them unsuitable as direct substitutes.
Quick answer: The table below contains XTCE model examples; it is not a DILM part-number table.

At a glance
In this guide
DILM and XT are Eaton low-voltage contactor product designations that appear in motor-control documentation. The important distinction for ordering is not simply “old versus new”: the exact model code identifies current rating, pole count, coil, auxiliary contacts and compatible accessories. Some XTCE catalogue codes are cross-referenced to DILM model descriptions in Eaton documentation, so check the manufacturer’s current cross-reference rather than assuming the names are interchangeable across every configuration.
A mismatch in the supplied draft has been corrected
The model table contains XTCE part numbers, not DILM part numbers. The revised table therefore labels them as XTCE examples. The XTCE032C10G code is shown with one normally-open auxiliary contact (1 NO), while XTCE032C01G is shown with one normally-closed auxiliary contact (1 NC); the source draft had the 10G configuration described incorrectly.
| Model number | Rated current in source | Poles | Auxiliary contact shown | Coil variant shown in source |
|---|---|---|---|---|
| XTCE040D00G | 40 A | 3P | 0 NO / 0 NC | 190 V AC, 50 Hz / 220 V AC, 60 Hz |
| XTCE032C10G | 32 A | 3P | 1 NO | 190 V AC, 50 Hz / 220 V AC, 60 Hz |
| XTCE032C01G | 32 A | 3P | 1 NC | 190 V AC, 50 Hz / 220 V AC, 60 Hz |
| XTCE025C01G | 25 A | 3P | 1 NC | Verify exact coil code |
| XTCE012B10G | 12 A | 3P | 1 NO | Verify exact coil code |
| XTCE009B01G | 9 A | 3P | 1 NC | Verify exact coil code |
The 040D00G coil specification is listed by Eaton as 190 Vac at 50 Hz / 220 Vac at 60 Hz. For other listed suffixes, verify the complete manufacturer data sheet rather than inferring coil voltage from the family alone.
A contactor can have the correct operational current and still be unusable if the coil voltage or frequency is wrong. Compare the actual control supply with the exact coil code on the part number, including 50 Hz / 60 Hz differences and whether the coil is AC or DC. Do not reduce a model number to its base family when requesting a quote or preparing a replacement order.
In the supplied XTCE examples, the 10 variant corresponds to one normally-open auxiliary contact and the 01 variant to one normally-closed auxiliary contact. The 00 variant in the XTCE040D00G example has no built-in auxiliary contact. This matters when the contactor state is used for PLC feedback, electrical interlocking or status indication. Confirm whether the application requires NO, NC or a separate auxiliary block.
For motor applications, compare rated operational current at the actual operating voltage and utilization category (commonly AC-3 for normal squirrel-cage motor starting and switching). Also check motor power, starting frequency, ambient temperature, enclosure conditions, overload relay compatibility and the required short-circuit coordination. A headline ampere figure without its rating conditions is not a complete selection basis.
No. Current alone does not establish interchangeability. Check coil voltage, auxiliary contacts, dimensions, terminals, accessories and motor-duty ratings.
For the supplied XTCE examples, 01 indicates one normally-closed auxiliary contact and 10 indicates one normally-open auxiliary contact. Confirm the exact model datasheet.
Do not generalize a suffix across all families or markets. Use the complete part number and the corresponding manufacturer datasheet.
Provide the complete DILM/XTCE code, motor voltage and power, coil supply, auxiliary-contact requirement and installed dimensions. That is the minimum useful information for a reliable cross-reference.
Before ordering: confirm the complete catalogue number, regional approvals, electrical ratings and compatible accessories in the latest manufacturer documentation.
Use these references for final engineering verification. Data in selection examples can vary by market, release and exact suffix.