New industry Technology regarding to Bussmann fuse, ABB breakers, Amphenol connectors, HPS transformers, etc.
DIN type current limiting fuse for transformer protection, we also call medium voltage fuse, HRC fuse, is traditional fuse over 100 years.
Key manufacturers are Eaton Bussmann, Cooper, ABB, EFEN, SIBA, MESA, ETI, Merlin Gerin, Elimsan, Inael, etc.
Fuse voltage: 3.6KV, 7.2kV, 12KV.
Since these fuses are made of the same industry standard- DIN standard.
All the similar fuses are repeatable and alternate.
We can find current limiting fuse near us, or with more lead-time, performance, price advantage.
Following are the fuse cross reference between manufacturers.
Eaton Bussmann | ABB | Cooper XR | SIBA | EFEN | MESA | ETI (80N Striker) | ETI (50N Striker) | Merlin Gerin | Elimsan | Inael |
3.6ADOSJ6.3 | 1YMB531001M0001 | NA | 3000213 | 67110060 | CF-7.2/6.3 | 4226005 | 4225005 | 51006 500 M0 | N/A | 3.6 IB-D2 6.3 |
3.6ADOSJ10 | 1YMB531001M0002 | NA | 3000213 | 67110100 | CF-7.2/10 | 4226006 | 4225006 | 51007.501.M0 | N/A | 3.6 IB-D2 10 |
3.6ADOSJ16 | 1YMB531001M0003 | NA | 3000213 | 67110160 | CF-7.2/16 | 4226007 | 4225007 | 51008 502.M0 | N/A | 3.6 IB-D2 16 |
3.6ADOSJ20 | N/A | NA | 3000213 | 67110200 | CF-7.2/20 | 4226008 | 4225008 | 51009 503 M0 | N/A | 3.6 IB-D2 20 |
3.6ADOSJ25 | 1YMB531001M000 | NA | 3000213 | 67110250 | CF-7.2/25 | 4226009 | 4225009 | 51010 504 M0 | N/A | 3.6 IB-D2 25 |
3.6ADOSJ31.5 | N/A | NA | 3000213 | 67110320 | CF-7.2/31.5 | 4226010 | 4225010 | 51011 505 M0 | N/A | 3.6 IB-D2 31.5 |
3.6ADOSJ40 | 1YMB53100M0005 | NA | 3000213 | 67110400 | CF-7.2/40 | 4226011 | 4225011 | 51012 506 M0 | N/A | 3.6 IB-D2 40 |
3.6WDOSJ50 | 1YMB531001M0006 | NA | 3000213 | 67110500 | CF-7.2/50 | 4226012 | 4225012 | 51013 507 M0 | N/A | 3.6 IB-D2 50 |
3.6WDOSJ63 | 1YMB531001M0007 | NA | 3001013 | 67110630 | CF-7.2/63 | 4226013 | 4225013 | 51014 508 M0 | N/A | 3.6 IB-D2 63 |
3.6WDOSJ80 | 1YMB531001M0008 | NA | 3001013 | 67110800 | CF-7.2/80 | 4226014 | 4225014 | 51015 509 M0 | N/A | 3.6 IB-D2 80 |
3.6WDOSJ100 | 1YMB531001M0009 | NA | 3001013 | 67110.1000 | CF-7.2/100 | 4226015 | 4225015 | 51016 510 M0 | N/A | 3.6 IB-D2 100 |
3.6WDOSJ125 | N/A | NA | 3001013 | 67110.1250 | N/A | 4226016 | 4225016 | N/A | N/A | N/A |
3.6WFOSJ160 | N/A | NA | 3001813 | 67110.1600 | N/A | 4226017 | 4225017 | N/A | N/A | N/A |
3.6WFOSJ200 | N/A | NA | 3001814 | 67210.2000 | N/A | N/A | N/A | N/A | N/A | N/A |
Eaton Bussmann | ABB | Cooper XR | SIBA | EFEN | MESA | ETI (80N Striker) | ETI (50N Striker) | Merlin Gerin | Elimsan | Inael |
7.2TDLSJ6.3 | 1YMB531034M0001 | SDLDJ-7.2kV/6.3A | 3009813 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TDLSJ10 | 1YMB531034M0002 | SDLDJ-7.2kV/10A | 3009813 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TDLSJ16 | 1YMB531034M0003 | SDLDJ-7.2kV/16A | 3009813 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TDLSJ20 | N/A | SDLDJ-7.2kV/20A | 3009813 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TDLSJ25 | 1YMB531034M0004 | SDLDJ-7.2kV/25A | 3009813 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TDLSJ31.5 | N/A | SDLDJ-7.2kV/31.5A | 3009813 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TDLSJ40 | 1YMB531034M0005 | SDLDJ-7.2kV/40A | 3009813 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TDLSJ50 | 1YMB531034M0006 | SDLDJ-7.2kV/50A | 3009813 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TDLSJ63 | 1YMB531034M0007 | SFLDJ-7.2kV/63A | 3009913 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TFLSJ80 | 1YMB531034M0008 | SFLDJ-7.2kV/80A | 3009913 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TFLSJ100 | 1YMB531034M0009 | SFLDJ-7.2kV/100A | 3009913 | N/A | N/A | N/A | N/A | N/A | N/A | N/A |
7.2TFLSJ125 | 1YMB531034M0010 | SKLDJ-7.2kV/125A | 3009913 | N/A | CF-7.2/125 | N/A | N/A | 757352 BN | N/A | N/A |
7.2TFLSJ160 | 1YMB531034M0011 | SXLDJ-7.2kV/160A | 3010013 | N/A | CF-7.2/160 | N/A | N/A | 757352 BP | N/A | N/A |
Eaton Bussmann | ABB | Cooper XR | SIBA | EFEN | MESA | ETI (80N Striker) | ETI (50N Striker) | Merlin Gerin | Elimsan | Inael |
12TDLEJ6.3 | 1YMB531042M0001 | SDLDJ-12KV/6.3A | 3000413 | 67120060 | CF-12/6.3 | 4236005 | 4235005 | 51006 511 M0 | ES 6509 006 | 12 IB-D1 6.3 |
12TDLEJ10 | 1YMB531042M0002 | SDLDJ-12KV/10A | 3000413 | 67120100 | CF-12/10 | 4236006 | 4235006 | 51006 512 M0 | ES 6509 010 | 12 IB-D1 10 |
12TDLEJ16 | 1YMB531042M0003 | SDLDJ-12KV/16A | 3000413 | 67120160 | CF-12/16 | 4236007 | 4235007 | 51006 513 M0 | ES 6509 016 | 12 IB-D1 16 |
12TDLEJ20 | 1YMB531042M0004 | SDLDJ-12KV/20A | 3000413 | 67120200 | CF-12/20 | 4236008 | 4235008 | 51006 514 M0 | ES 6509 020 | 12 IB-D1 20 |
12TDLEJ25 | 1YMB531002M0004 | SDLDJ-12KV/25A | 3000413 | 67120250 | CF-12/25 | 4236009 | 4235009 | 51006 515 M0 | ES 6509 025 | 12 IB-D1/D2 25 |
12TDLEJ31.5 | 1YMB531002M0014 | SDLDJ-12KV/31.5A | 3000413 | 67120320 | CF-12/31.5 | 4236010 | 4235010 | 51006 516 M0 | ES 6509 030 | 12 IB-D1/D2 31.5 |
12TDLEJ40 | 1YMB531002M0005 | SDLDJ-12KV/40A | 3000413 | 67120400 | CF-12/40 | 4236011 | 4235011 | 51006 517 M0 | ES 6509 040 | 12 IB-D1/D2 40 |
12TDLEJ50 | 1YMB531002M0006 | SDLDJ-12KV/50A | 3000413 | 67120500 | CF-12/50 | 4236012 | 4235012 | 51006 518 M0 | ES 6509 050 | 12 IB-D2 50 |
12TDLEJ63 | 1YMB531002M0007 | SDLDJ-12KV/63A | 3001213 | 67120630 | CF-12/63 | 4236013 | 4235013 | 51006 519 M0 | ES 6509 063 | 12 IB-D2 63 |
12THLEJ80 | 1YMB531002M0021 | SDLDJ-12KV/80A | 3001213 | 67120800 | CF-12/80 | 4236014 | 4235014 | 51006 520 M0 | ES 6509 080 | 12 IB-D3 80 |
12THLEJ100 | 1YMB531002M0022 | SFLDJ-12kV/100A | 3001213 | 67120.1000 | CF-12/100 | 4236015 | 4235015 | 51006 521 M0 | ES 6509 100 | 12 IB-D3 100 |
12TKLEJ125 | 1YMB531043M0010 | SKLDJ-12kV/125A | 3001213 | 67120.1250 | N/A | 4236016 | 4235016 | N/A | N/A | N/A |
12TXLEJ160 | N/A | SXLDJ-12kV/160A | 3002013 | 67220.1600 | N/A | 4236017 | 4235017 | N/A | N/A | N/A |
12TXLEJ200 | N/A | SXLDJ-12kV/200A | 3002014 | 67220.2000 | N/A | N/A | N/A | N/A | N/A | N/A |
12THMEJ100 | 1YMB531035M0022 | SFMDJ-12kV/100A | 3010213 | 67004-1000 | CF-12/100 | 4236515 | 4235515 | 757364CN | N/A | N/A |
12TFMSJ160 | 1YMB531035M0011 | SKMDJ-12kV/160A | 3010313 | 67004-1600 | CF-12/160 | 4236517 | 4235517 | 757354C | N/A | N/A |
1, Since transformer/ Switchgear is with 3 poles. All the current limiting fuse for transformer protection is packed in 3 PCS.
If you change the fuse link, pls do remember to change 3PCS at the same time.
2, Do not use the different manufacturers but same current/voltage current limiting fuse, Because different manufacturers with different internal fuse design, the fuse characteristics, and resistance are not similar if mixing, it will cause the 3 poles voltage not in balance. The system is easily to have problem and fuse is more easily melting in sudden.
What's current limiting fuse type?
What's non current limiting fuse?
How to test current limiting fuse?
New industry Technology regarding to Bussmann fuse, ABB breakers, Amphenol connectors, HPS transformers, etc.