Product Name | Eaton Bussmann series KRP-C fuse Class L Low Peak |
Catolog Number | KRP-C-5000SP |
Rated Amperage | 5000A |
Rated Voltage | 600VAC, 300VDC |
Datasheet | |
Product Height | 10.75 in |
Product Diameter | 7.17 in |
Product Weight | 27lb |
Class | Time Delay |
Voltage Type | AC, DC |
Class | Class L Fuse |
Breaking Capacity | 300 kA RMS Sym, 100 kA DC |
3D Model; CAD | stp |
Connection | Bolted |
Agency Information | UL Listed 248-10, Guide JFHR, File E56412, CSA Certified, Class 1422-02, File 53787, Class L per CSA C22.2, No 248.10, RoHS compliant, CE |
• Large distribution switchboards
• Power panelboards
• Large machinery disconnects
KRP-C-601SP | KRP-C-1000SP | KRP-C-1800SP | KRP-C-3500SP |
KRP-C-650SP | KRP-C-1100SP | KRP-C-1900SP | KRP-C-4000SP |
KRP-C-700SP | KRP-C-1200SP | KRP-C-2000SP | KRP-C-4500SP |
KRP-C-750SP | KRP-C-1350SP | KRP-C-2001SP | KRP-C-5000SP |
KRP-C-800SP | KRP-C-1400SP | KRP-C-2400SP | KRP-C-6000SP |
KRP-C-801SP | KRP-C-1500SP | KRP-C-2500SP | |
KRP-C-900SP | KRP-C-1600SP | KRP-C-3000SP |
Features:
• Industry's only UL Listed and CSA Certified fuse with a 300kA interrupting rating that allows for simple, worry-free installation in virtually any application.
• Fast short-circuit protection and dual-element, time-delay performance provide ultimate protection. • Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak fuses.
• Consistent 2:1 ampacity ratios for all Low-Peak fuses make selective coordination easy.
• Time-delay for close sizing load.
• Current-limiting action of the fuse generally affords considerable reduction in bus bracing.
• All-purpose silver-linked fuse for both overload and shortcircuit protetion for high capacity systems (mains and large feeders).
• O-ring seals maximize pressure build-up during current limiting action and ensure filter retention.
• High-grade silica sand filler accelerates response of fuse to short-circuits by having quenching effect on the fuse arc.
• 99.9% Pure silver links provide low watt loss with low operating temperature on normal current levels and minimizes total clearing I2 t fault energy left-through.
You can ask any Bussmann fuse and fuse cross reference.
Energy Storage System Electrical Protection Solution, Fuse,Pyrofuse, Breaker, Bussmann, Eaton, Litte.....
MOREBussmann fuse catalog, EV fuse,DIN type fuse, type.....
MOREEaton Bussmann 1000VDC 400A,high speed breaker...
MOREEnergy Storage System Electrical Protection Solution, Fuse,Pyrofuse, Breaker, Bussmann, Eaton, Litte.....
MOREBussmann fuse catalog, EV fuse,DIN type fuse, type.....
MOREFuses compliant with the specifications for current limiting fuses should be marked as "Current Limi.....
MORE