You can ask any Bussmann fuse and fuse cross reference.
Description
Eaton’s Bussmann series pre-production and sample electric vehicle square body fuse links have been specifically selected and designed to meet the power requirement for battery and drive inverter protection,
as well as DC charging and short-circuit back-up protection. Therefore, we offer a range of standardised 500Vd.c. and 1000Vd.c. production samples for incorporation in test program.
Catalogue symbol
Rated voltage | ||
Fuse body sizes | 500 V d.c. | 1000 V d.c. |
1 | XEV1XSQ-Amps-V | XEV1XSQ-Amps-V |
2 | XEV1SQ-Amps-V | XEV1SQ-Amps-V |
3 | XEV2SQ-Amps-V | XEV2SQ-Amps-V |
Technical data | ||||||
Catalogue number with bolted blade | Fuse body size | Rated current (Amps) | Rated voltage (V d.c.) | Pre-arcing l2t | Power loss at 0.5 x 1 (W) n | Power loss at ln (W) |
XEV1XSQ-250 | r | 250 | 500 | 4,200 | 8 | 40 |
XEV1XSQ-315 | 1* | 315 | 500 | 7,000 | 10 | 50 |
XEV1XSQ-350 | 1* | 350 | 500 | 10,000 | 10 | 55 |
XEV1XSQ-400 | 1* | 400 | 500 | 15,000 | 11 | 60 |
XEV1XSQ-450 | 1* | 450 | 500 | 21,000 | 12 | 65 |
XEV1XSQ-500 | r | 500 | 500 | 27,000 | 13 | 70 |
XEV1XSQ-550 | 1* | 550 | 500 | 34,000 | 14 | 75 |
XEV1XSQ-630 | 1* | 630 | 500 | 48,500 | 15 | 80 |
XEV1SQ-700 | 1 | 700 | 500 | 69,500 | 16 | 85 |
XEV1SQ-800 | 1 | 800 | 500 | 105,000 | 18 | 95 |
XEV2SQ-900 | 2 | 900 | 500 | 125,000 | 21 | 110 |
XEV2SQ-1K0 | 2 | 1,000 | 500 | 180,000 | 22 | 115 |
You can ask any Bussmann fuse and fuse cross reference.
Energy Storage System Electrical Protection Solution, Fuse,Pyrofuse, Breaker, Bussmann, Eaton, Litte.....
MOREBussmann fuse catalog, EV fuse,DIN type fuse, type.....
MOREEaton Bussmann 1000VDC 400A,high speed breaker...
MOREEnergy Storage System Electrical Protection Solution, Fuse,Pyrofuse, Breaker, Bussmann, Eaton, Litte.....
MOREBussmann fuse catalog, EV fuse,DIN type fuse, type.....
MOREFuses compliant with the specifications for current limiting fuses should be marked as "Current Limi.....
MORE