Product Name | Eaton Bussmann series LPN-RK Class RK1 Fuse |
Catolog Number | LPN-RK-90SP |
Rated Amperage | 90A |
Rated Voltage | 250VAC, 125VDC |
Datasheet | |
Product Length | 5.88 in |
Product Diameter | 1.1 in |
Product Weight | 1.25 lb |
Class | Time Delay |
Voltage Type | AC, DC |
Class | Class RK1 Fuse |
Breaking Capacity | • 300 kA RMS Sym. • 100 kA DC |
3D Model; CAD | stp |
Connection | Ferrule end x ferrule end |
Agency Information | UL Listed, Guide JDDZ, File E4273, CSA Certified, Class RK1 per CSA C22.2, No 248.12, Class 1422-02, File 53787, CE |
LPN-RK-1/10SP | LPN-RK-2/10SP | LPN-RK-3/10SP | LPN-RK-4/10SP | LPN-RK-15/100SP |
LPN-RK-6/10SP | LPN-RK-8/10SP | LPN-RK-1SP | LPN-RK-1-1/8SP | LPN-RK-1-1/4SP |
LPN-RK-1-4/10SP | LPN-RK-1-6/10SP | LPN-RK-1-8/10SP | LPN-RK-2SP | LPN-RK-2-1/4SP |
LPN-RK-2-1/2SP | LPN-RK-2-8/10SP | LPN-RK-3SP | LPN-RK-3-2/10SP | LPN-RK-3-1/2SP |
LPN-RK-4SP | LPN-RK-4-1/2SP | LPN-RK-5SP | LPN-RK-5-6/10SP | LPN-RK-6SP |
LPN-RK-6-1/4SP | LPN-RK-8SP | LPN-RK-9SP | LPN-RK-10SP | LPN-RK-12SP |
LPN-RK-15SP | LPN-RK-17-1/2SP | LPN-RK-20SP | LPN-RK-25SP | LPN-RK-30SP |
LPN-RK-35SP | LPN-RK-40SP | LPN-RK-45SP | LPN-RK-50SP | LPN-RK-60SP |
LPN-RK-70SP | LPN-RK-80SP | LPN-RK-90SP | LPN-RK-100SP | LPN-RK-110SP |
LPN-RK-125SP | LPN-RK-150SP | LPN-RK-175SP | LPN-RK-200SP | LPN-RK-225SP |
LPN-RK-250SP | LPN-RK-300SP | LPN-RK-350SP | LPN-RK-400SP | LPN-RK-450SP |
LPN-RK-500SP | LPN-RK-600SP |
• Large distribution switchboards
• Power panelboards
• Motor control centers
• Machinery disconnect switches
Features
• Separate overload and short-circuit elements provide time delay for close sizing of high inrush loads linked with RK1 current-limitation and selective coordination ratio of 2:1 (within Low-Peak fuse family) helps prevent widespread blackouts
• Inventory consolidation of Class RK1, RK5 and H fuses for reduced SKU investment and minimizing potential for misapplying fuse
• 300 kA RMS symmetrical interrupting rating provides adequate ratings without obsolescence for all electrical systems, big or small
• Insulated end caps reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
You can ask any Bussmann fuse and fuse cross reference.
Energy Storage System Electrical Protection Solution, Fuse,Pyrofuse, Breaker, Bussmann, Eaton, Litte.....
MOREBussmann fuse catalog, EV fuse,DIN type fuse, type.....
MOREEaton Bussmann 1000VDC 400A,high speed breaker...
MOREEnergy Storage System Electrical Protection Solution, Fuse,Pyrofuse, Breaker, Bussmann, Eaton, Litte.....
MOREBussmann fuse catalog, EV fuse,DIN type fuse, type.....
MOREFuses compliant with the specifications for current limiting fuses should be marked as "Current Limi.....
MORE