LPN-RK-40SP Bussmann Low Peak Time Delay Class RK1 Fuse

LPN-RK-40SP Bussmann Low Peak Time Delay Class RK1 Fuse

Manufacturer:Bussmann

Description :40A 250VAC, 125VDC, Low Peak Time Delay Dual Element Class RK1 Fuse, Slow Blowing Fuse

Stock quantity(PCS) :0

Lead time ( Weeks ) :12

Categories:Power Fuses, inverter fuse, Motor Protection, bolt on fuse, Buss Fuses

Browse:

  • Specification
  • Datasheet download

LPN-RK-40SP Bussmann Low Peak Dual Element Class RK1 Fuse 

Product NameEaton Bussmann series LPN-RK Class RK1 Fuse
Catolog NumberLPN-RK-40SP
Rated Amperage40A
Rated Voltage250VAC, 125VDC
DatasheetPDF
Product Length3 in
Product Diameter0.81 in
Product Weight1.2 lb
ClassTime Delay
Voltage TypeAC, DC
ClassClass RK1 Fuse
Breaking Capacity• 300 kA RMS Sym.
• 100 kA DC
3D Model; CADstp
ConnectionFerrule end x ferrule end
Agency Information UL Listed, Guide JDDZ, File E4273, CSA Certified, Class RK1 per CSA C22.2, No 248.12, Class 1422-02, File 53787, CE



Catalog no. (amps)

LPN-RK-1/10SPLPN-RK-2/10SPLPN-RK-3/10SPLPN-RK-4/10SPLPN-RK-15/100SP
LPN-RK-6/10SPLPN-RK-8/10SPLPN-RK-1SPLPN-RK-1-1/8SPLPN-RK-1-1/4SP
LPN-RK-1-4/10SPLPN-RK-1-6/10SPLPN-RK-1-8/10SPLPN-RK-2SPLPN-RK-2-1/4SP
LPN-RK-2-1/2SPLPN-RK-2-8/10SPLPN-RK-3SPLPN-RK-3-2/10SPLPN-RK-3-1/2SP
LPN-RK-4SPLPN-RK-4-1/2SPLPN-RK-5SPLPN-RK-5-6/10SPLPN-RK-6SP
LPN-RK-6-1/4SPLPN-RK-8SPLPN-RK-9SPLPN-RK-10SPLPN-RK-12SP
LPN-RK-15SPLPN-RK-17-1/2SPLPN-RK-20SPLPN-RK-25SPLPN-RK-30SP
LPN-RK-35SPLPN-RK-40SPLPN-RK-45SPLPN-RK-50SPLPN-RK-60SP
LPN-RK-70SPLPN-RK-80SPLPN-RK-90SPLPN-RK-100SPLPN-RK-110SP
LPN-RK-125SPLPN-RK-150SPLPN-RK-175SPLPN-RK-200SPLPN-RK-225SP
LPN-RK-250SPLPN-RK-300SPLPN-RK-350SPLPN-RK-400SPLPN-RK-450SP
LPN-RK-500SPLPN-RK-600SP




 


LPN-RK Fuse Typical applications

• Large distribution switchboards

• Power panelboards

• Motor control centers

• Machinery disconnect switches

 

 LPN-RK Fuse Dimension: -in

LPN-RK Fuse Dimension: -in 35-60A.png




Features

• Separate overload and short-circuit elements provide time delay for close sizing of high inrush loads linked with RK1 current-limitation and selective coordination ratio of 2:1 (within Low-Peak fuse family) helps prevent widespread blackouts

• Inventory consolidation of Class RK1, RK5 and H fuses for reduced SKU investment and minimizing potential for misapplying fuse

• 300 kA RMS symmetrical interrupting rating provides adequate ratings without obsolescence for all electrical systems, big or small

• Insulated end caps reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing